Single Duct Terminal Unit, Steel, w/Optional Digital Controls

Variable Air Volume Systems supply a constant temperature to an area and varies the volume as opposed to a conventional HVAC system which supplies a constant volume and varies the air temperature.  

 

Operating costs are greatly reduced compared to the larger conventional HVAC systems by using less fan energy and less refrigeration energy. Variable Air Volume Systems also cut initial cost by taking advantage of

FEATURES:

  • 16 ga. (1.63) corrosion-resistant steel inclined opposed blade damper with seals. 45° rotation. 1/2" (13) dia. plated steel drive shaft. An indicator mark on the end of the shaft shows damper position. Tight close-off. Damper leakage is less than 2% of nominal flow at 3" w.g. (750 Pa). 
  • Inclined opposed blade valve is inherently more linear in its flow characteristics than the standard butterfly type damper. More accurate flow control is ensured, which reduces hysteresis for more stable control of the temperature in the zone.
  • Available in 11 unit sizes to handle from 215 – 6435 cfm (101 – 3037 l/s). • Compact low profile design to accommodate tight ceiling spaces. Maximum unit height is only 12 1/2" (318)  for sizes 4 through 16 [up to 3730 cfm (1761 l/s)]. Unit sizes 4 through 10 feature round inlets and 12 through 16 feature flat oval equivalent inlets.
  • Gauge taps provided for field calibration and balancing.
  • Multi-point averaging Diamond Flow Sensor for pressure independent applications.
  • 22 ga. (0.86) zinc coated steel casing, mechanically sealed, low leakage construction.
  • Rectangular discharge with slip and drive cleat duct connection.
  • 3/4" (19) dual density insulation maximizes acoustical and thermal performance. 4 lb. high density skin is treated to resist abrasion and erosion from airflow. Edges are coated. Meets requirements of NFPA 90A and UL 181.
  • Single point electrical or pneumatic main air connection.
  • Right-hand controls location is standard (shown) when looking in direction of airflow. Damper is CW to close. Optional left hand controls mounting is available, when damper is CCW to close.
  • Independently tested and certified laboratory performance data.

 

 

Product Detail

Product Performance

Product Specification

Related items

  • 33SZ 33SZ

    Model Series 33SZ is a Fan Powered Chilled Water Terminal Unit with Sensible Cooling (DOAS) featuring an ultra-high efficiency ECM, fan motor and EPIC fan volume controller. Both standard height and low profile units are available.

  • 35SST 35SST
  • 30HQ 30HQ

    Hospital system designs have to contend with the presence of infectious diseases, chemical hazards, biological contaminants and low sound level requirements. The 30HQ hospital grade terminal unit has been purposely designed to address these parameters by using innovative options and construction methods, resulting in simplified maintenance and improved sound performance.

  • 30HQX 30HQX

    The 30HQX Hospital Grade exhaust terminal unit has been purposely designed to provide optimum performance, while addressing the needs of hospital and other critical environment applications where indoor air quality (IAQ) is a concern. Standard features, like the access door and removable flow sensor, ensure that maintenance is simplified.

  • 37S 37S

    The 37S Series Low Profile terminals are designed for shallow ceiling plenum applications and therefore limited to 11" (279) in height. Shallow plenums are common where zoning requirements limit building height. When building height is constrained, building designers will maximize the number of floors by reducing the distance between floors, requiring low profile products like the 37S Series.